Determination of meropenem in endotracheal tubes by in-tube solid phase microextraction coupled to capillary liquid chromatography with diode array d…

2017

Meropenem is a widely used antimicrobial for the treatment of infections associated with the use of invasive medical devices in intensive care unit patients. These treatments are not always effective, in fact, in-vitro studies have demonstrated the difficulty of antimicrobials to penetrate into the biofilm, however in-vivo studies of the effect of these compounds is a trend, mostly because of the complexity of pulmonary samples extracted from ETTs. Therefore, the objective of this study was to evaluate in-tube solid phase microextraction (in-tube SPME) coupled to capillary liquid chromatography (CapLC) with DAD to determine meropenem in Errs in order to estimate the penetration capability i…

0301 basic medicineCapillary action030106 microbiologyClinical BiochemistryPharmaceutical ScienceEndotracheal tubesengineering.materialSolid-phase microextraction01 natural sciencesMeropenemAnalytical Chemistry03 medical and health sciencesCapillary columnCoatingCapillary ElectrochromatographyLimit of DetectionCapillary-LC-DADDrug DiscoverymedicineIntubation IntratrachealHumansSpectroscopySolid Phase MicroextractionChromatographyChemistryBiofilm010401 analytical chemistryIn-tube SPMEPenetration (firestop)MeropenemDiode array0104 chemical sciencesAnti-Bacterial AgentsCapillary lengthengineeringThienamycinsmedicine.drugChromatography LiquidJournal of pharmaceutical and biomedical analysis
researchProduct

Preparation and characterization of octadecyl acrylate monoliths for capillary electrochromatography by photochemical, thermal, and chemical initiati…

2013

Monolithic stationary phases based on octadecyl acrylate for CEC using different initiating systems (UV irradiation, thermal, and chemical initiation) in the presence of lauroyl peroxide as initiator were synthesized. For each initiation mode, the influence of the porogenic solvent composition on both the morphological and electrochromatographic properties of the resulting monoliths was investigated. Under optimal conditions, excellent efficiencies for the photochemically and chemically polymerized monoliths (minimum plate heights of 6.9–10.7 and 6.5–12.6 μm, respectively) were achieved. Thermally initiated columns gave lower efficiency values, permeabilities, and longer analysis times comp…

AcrylateCapillary electrochromatographyChromatographyMaterials scienceFiltration and SeparationLauroyl peroxideAnalytical ChemistryCharacterization (materials science)chemistry.chemical_compoundPolymerizationchemistryChemical engineeringThermalIrradiationSolvent compositionJournal of Separation Science
researchProduct

Chemical initiation for butyl and lauryl acrylate monolithic columns for CEC.

2009

Butyl acrylate (BA)- and lauryl acrylate (LA)-based monolithic stationary phases for CEC were synthesized, using a redox system as initiator of polymerization. BA monoliths were initiated with ammonium peroxodisulfate, whereas LA columns were obtained with lauroyl peroxide as initiator. In both cases, TEMED was used to activate the process. The influence of porogenic solvent composition on both morphological and electrochromatographic properties of the resulting monoliths was investigated. Excellent efficiencies (minimum plate heights of 4.2-6.3 microm for BA columns and 2.6-5.3 microm for LA stationary phases, for a PAHs mixture) were achieved. The capability of separation of both types of…

AcrylateLipid PeroxidesButyl acrylateClinical BiochemistryInorganic chemistryReproducibility of ResultsLauroyl peroxideEthylenediaminesBiochemistryRedoxAnalytical Chemistrychemistry.chemical_compoundchemistryPolymerizationAcrylatesAmmonium SulfateCapillary ElectrochromatographyMicroscopy Electron ScanningAmmoniumSolvent compositionPolycyclic Aromatic HydrocarbonsGonadal Steroid HormonesNuclear chemistryElectrophoresis
researchProduct

Ion-pair in-tube solid-phase microextraction and capillary liquid chromatography using a titania-based column: application to the specific lauralkoni…

2012

Abstract A quick, miniaturized and on-line method has been developed for the determination in water of the predominant homologue of benzalkonium chloride, dodecyl dimethyl benzyl ammonium chloride or lauralkonium chloride (C 12 -BAK). The method is based on the formation of an ion-pair in both in-tube solid-phase microextraction (IT-SPME) and capillary liquid chromatography. The IT-SPME optimization required the study of the length and nature of the stationary phase of capillary and the processed sample volume. Because to the surfactant character of the analyte both, the extracting and replacing solvents, have played a decisive role in the IT-SPME optimized procedure. Conditioning the capil…

Capillary actionDetergentsAnalytical chemistrySolid-phase microextractionBiochemistryChlorideAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionmedicineSolid Phase Microextractionchemistry.chemical_classificationDetection limitTitaniumCapillary electrochromatographyChromatographyChemistryOrganic ChemistryWaterGeneral MedicineAmmonium chlorideCounterionBenzalkonium CompoundsAmmonium acetateWater Pollutants Chemicalmedicine.drugChromatography LiquidJournal of chromatography. A
researchProduct

Acrylate ester-based monolithic columns for capillary electrochromatography separation of triacylglycerols in vegetable oils

2011

Abstract A simple and reliable method for the evaluation of triacylglycerols (TAGs) in vegetable oils by capillary electrochromatography (CEC) with UV–Vis detection, using octadecyl acrylate (ODA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained at the following ratios: 40:60% (wt/wt) monomers/porogens, 60:40% (wt/wt) ODA/1,3-butanediol diacrylate and 23:77% (wt/wt) 1,4-butanediol/1-propanol (14 wt% 1,4-butanediol in the polymerization mixture). A satisfactory resolution between TAGs was achieved in less than 12 min with a 65:35 (v/v…

Capillary electrochromatographyAcrylategeographyChromatographygeography.geographical_feature_categoryResolution (mass spectrometry)Organic ChemistryDiscriminant Analysis1-PropanolGeneral MedicineBiochemistryAnalytical Chemistrychemistry.chemical_compoundMonomerVegetable oilAcrylateschemistryPolymerizationCapillary ElectrochromatographyMicroscopy Electron ScanningPlant OilsMonolithButylene GlycolsAmmonium acetateTriglyceridesJournal of Chromatography A
researchProduct

Preparation and characterization of hexyl methacrylate monolithic columns for CEC

2008

The preparation of hexyl methacrylate (HMA) monolithic columns for CEC separations has been investigated with two initiation systems: (i) ammonium peroxodisulphate and TEMED to activate the polymerization reaction, and (ii) by thermal initiation with AIBN. For both initiators, the influence of composition of porogenic solvent on morphological and chromatographic properties of monoliths was investigated. Two porogenic solvent systems, aqueous and non-aqueous media, were also studied for monolithic beds polymerized with AIBN. Under optimal conditions, low minimum plate heights (9.6 mum for peroxodisulphate, 8.4 and 10.0 mum for AIBN in aqueous and non-aqueous porogenic solvents, respectively)…

Capillary electrochromatographyChromatographyAqueous solutionChemistryClinical BiochemistryAcrylic ResinsReproducibility of ResultsRepeatabilityEthylenediaminesMethacrylateBiochemistryAnalytical ChemistrySolventPolymerizationCapillary Electrochromatographyvisual_artMicroscopy Electron Scanningvisual_art.visual_art_mediumMethacrylatesAcrylic resinHexyl methacrylateELECTROPHORESIS
researchProduct

Pressurized flow electrochromatography with reversed phase capillary columns

1995

Pressurized flow electrochromatography (PEC) is a hybrid of capillary LC and capillary electroendosmotic chromatography (CEC). Both a pressure gradient and an electric field are applied across a packed capillary. The feasability of a simple, easy to handle PEC instrumentation is demonstrated. Home made capillary columns with four different silica-based reversed phase packings have been operated under PEC conditions separating non ionic and ionic low molecular weight analytes. The capillary columns have been characterized with respect to their separation efficiency and selectivity and the results have been compared to those obtained with the purely pressure driven system. An electrochromatog…

Capillary electrochromatographyChromatographyCapillary electrophoresisElectrochromatographyChemistryCapillary actionPhase (matter)Analytical chemistryReversed-phase chromatographyBiochemistryCapacity factorPressure gradientAnalytical ChemistryFresenius' Journal of Analytical Chemistry
researchProduct

Influence of temperature on the behaviour of small linear peptides in capillary electrochromatography

2000

The influence of temperature, T, on the retention times, peak widths, peak symmetry coefficients and theoretical plate numbers of two small linear peptides, [Met5]enkephalin and [Leu5]enkephalin, has been studied with capillary electrochromatography (CEC) capillary columns of 100 microm I.D. and 250 mm packed length with a total length of 335 mm, containing 3 microm Hypersil n-octadecyl bonded silica. With increasing column temperature from 15 to 60 degrees C, the electroosmotic flow (EOF) and the column efficiencies increased, whereas the retention coefficients (Kcec) of both peptides decreased. A linear relationship was found between the EOF value and the square root of the temperature ov…

Capillary electrochromatographyChromatographyChemistryCapillary actionOrganic ChemistryTemperatureAnalytical chemistryElectro-osmosisGeneral MedicineReversed-phase chromatographyAtmospheric temperature rangeBiochemistryAnalytical ChemistryColumn chromatographyElectrochromatographyTheoretical platePeptidesChromatography Micellar Electrokinetic CapillaryJournal of Chromatography A
researchProduct

Peroxodisulfate as a chemical initiator for methacrylate-ester monolithic columns for capillary electrochromatography

2008

Organic monolithic stationary phases for CEC were synthesized in situ in fused-silica capillaries. Polymerization mixtures were composed of butyl methacrylate, ethylene dimethacrylate, and [2-(methacryloyloxy)ethyl]trimethyl ammonium chloride in the presence of a porogenic solvent, using ammonium peroxodisulfate as chemical initiator, and N,N,N',N'-tetramethylethylenediamine to activate the reaction. The influence of the amount of initiator, temperature, and composition of porogenic solvent on the physical and chromatographic properties of monolithic stationary phases has been investigated. A minimum plate height of 14.5 microm was obtained at 18 wt% of 1,4-butanediol in the polymerization …

Capillary electrochromatographyChromatographySilicon dioxideClinical BiochemistryAcrylic ResinsAzobisisobutyronitrileEthylenediaminesSilicon DioxideMethacrylateBiochemistryAnalytical ChemistrySolventchemistry.chemical_compoundchemistryPolymerizationAmmonium SulfateCapillary ElectrochromatographyNitrilesMethacrylatesAmmoniumAmmonium chloridePorosityNuclear chemistryELECTROPHORESIS
researchProduct

A critical appraisal of capillary electrochromatography.

2002

Although still in its infancy, CEC promises some advantages over competitive techniques for separating charged analytes including biomolecules.

Capillary electrochromatographyCritical appraisalSpectrometry Mass Electrospray IonizationChemistryElectrophoresis CapillaryProteinsNanotechnologyEquipment DesignPeptidesChromatography High Pressure LiquidAnalytical ChemistryAnalytical chemistry
researchProduct